Thank you for taking an interest in part number 713.1202, a Toroid Corp product we have in stock that is listed alongside the NSN 6120014699388 and the description “Transformer Power.” As part number 713.1202 is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number 713.1202 is listed alongside the NSN 6120-01-469-9388, meaning that it also belongs to FSC 6120 Transformers Distribution and Power Station. Furthermore, this NSN part is specifically manufactured under CAGE Code 0FZR3, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6120-01-469-9388 Item PartTypeName: TRANSFORMER,POWER | 6120 | 014699388 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CTR015 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | Mounting Hole Diameter | 0.250 INCHES NOMINAL SINGLE GROUP |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CBBL | Features Provided | COLOR CODED LEAD AND PROTECTIVE COVER AND SPECIAL MARKING |
ADAU | Body Height | 1.900 INCHES NOMINAL |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | Winding Operating Current | 0.6 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CRBZ | Winding Operating Current | 0.7 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
ACZF | Maximum Transformer Power Rating | 150.0 VOLT-AMPERE SINGLE COMPONENT |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
FEAT | Special Features | SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66 |
ADAR | Body Outside Diameter | 3.900 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
AKNA | Inclosure Type | FULLY INCLOSED |