Thank you for taking an interest in part number PP11-1-0.500A-0B-V, a Sensata Technologies Inc product we have in stock that is listed alongside the NSN 5925015756956 and the description “Circuitbreaker.” As part number PP11-1-0.500A-0B-V is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number PP11-1-0.500A-0B-V is listed alongside the NSN 5925-01-575-6956, meaning that it also belongs to FSC 5925 Circuit Breakers. Furthermore, this NSN part is specifically manufactured under CAGE Code 82647, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-575-6956 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015756956 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PP11-1-0.500A-0B-V | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCY | Part Name Assigned By Controlling Agency | CAGE: SNAPAK SERIES MAGNETIC CIRCUIT PROTECTOR |
AKPX | Pole Quantity | 1 |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 SINGLE LOCATION |
ADAT | Body Width | 1.304 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
AXHR | Mounting Facility Type And Quantity | 4 TERMINAL |
AGAV | End Item Identification | C-10256C/BRR-6 TRIDENT, CONTROL INDICATOR; C-10256D/BRR-6 TRIDENT, CONTROL INDICATOR; OHIO CLASS SSBN |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 4 KNIFE BLADE |
MRC | Decoded Requirement | Clear Text Reply |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABHP | Overall Length | 1.375 NOMINAL INCHES |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 8.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.