Thank you for taking an interest in part number A30-182, a Ranco Management Corp product we have in stock that is listed alongside the NSN 5930004820137 and the description “Switch Thermostatic.” As part number A30-182 is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number A30-182 is listed alongside the NSN 5930-00-482-0137, meaning that it also belongs to FSC 5930 Switches. Furthermore, this NSN part is specifically manufactured under CAGE Code 49742, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-482-0137 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 004820137 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MRB412 | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AEVT | CAPILLARY TUBE LENGTH | 42.000 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES MOTOR LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 20.0 AMPERES MOTOR LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE,PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | -4.00 TO 48.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB WITH SCALE |
CTYX | CONTACT STIMULUS RATING | 14.00 DIFFERENTIAL POINT MINIMUM DEGREES FAHRENHEIT AND 20.00 DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 277.0 AC AT SEA LEVEL SECOND VOLTAGE |