Thank you for taking an interest in part number 587R294H15, a Microwave Applications Group Inc product we have in stock that is listed alongside the NSN 5985013341108 and the description “Waveguideassembly.” As part number 587R294H15 is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number 587R294H15 is listed alongside the NSN 5985-01-334-1108, meaning that it also belongs to FSC 5985 Antennas Waveguides and Related Equipment. Furthermore, this NSN part is specifically manufactured under CAGE Code 63661, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-334-1108 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 013341108 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | S | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
587R294H15 | 6 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIFTH TUBING SEGMENT |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
SFTT | SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PASSIVATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PRIMER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES |
AGAV | END ITEM IDENTIFICATION | F-16 |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS THIRD TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM ALL FLANGES AND 0.904 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM ALL FLANGES AND 0.453 INCHES MAXIMUM ALL FLANGES |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
FLEX | FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | SILVER ALL TUBING SEGMENT INSIDE SURFACES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIP. |
AAJF | THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SECOND TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHRW | TUBING TWIST TYPE | STRAIGHT TWIST SECOND TUBING SEGMENT |
AHRX | TUBING TWIST ANGLE IN DEG | 90.0 SECOND TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.35 |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CTCJ | FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEX | FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIFTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SIXTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
PMLC | PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNC ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SIXTH TUBING SEGMENT |
AHSY | FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM ALL FLANGES AND 0.404 INCHES MAXIMUM ALL FLANGES |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTX | INSERTION LOSS IN DECIBELS | 0.25 |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FEAT | SPECIAL FEATURES | FLANGES HAVE RESONANCE SUPPRESSOR AND CAPTURED SCREWS INCLUDED WITH EACH FLANGE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.