Thank you for taking an interest in part number AM2S-Z272-1W, a Heinemann Electric Co Inc product we have in stock that is listed alongside the NSN 5925014677122 and the description “Circuit Breaker.” As part number AM2S-Z272-1W is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number AM2S-Z272-1W is listed alongside the NSN 5925-01-467-7122, meaning that it also belongs to FSC 5925 Circuit Breakers. Furthermore, this NSN part is specifically manufactured under CAGE Code L3330, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-467-7122 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014677122 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM2S-Z272-1W | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 12.0 DC SECOND LOCATION |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
ADAT | Body Width | 1.500 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |
AJWX | Mounting Surface To Terminal End Distance | 2.850 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.125 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 78.6 AMPERES DC FIRST LOCATION |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |