Thank you for taking an interest in part number SR03A, a Hdl Research Lab Inc product we have in stock that is listed alongside the NSN 6130012920776 and the description “Powersupply.” As part number SR03A is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number SR03A is listed alongside the NSN 6130-01-292-0776, meaning that it also belongs to FSC 6130 Converters Electrical Non Rotating. Furthermore, this NSN part is specifically manufactured under CAGE Code 66015, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-292-0776 Item PartTypeName: POWER SUPPLY | 6130 | 012920776 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SR03A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 7.120 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.120 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.880 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | EC135 WWABNCP GP-B |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 120.8 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND-16.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 16.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
CBBL | FEATURES PROVIDED | VOLTAGE ADJUSTMENT AND OVER VOLTAGE PROTECTOR AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 42.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | THREADED STUD SINGLE POWER OUTPUT AND CONNECTOR,RECEPTACLE SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | CONNECTOR,PLUG SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
CWWY | POWER SUPPLY EFFICIENCY LINE | 70.0 |
NHCF | NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |