Thank you for taking an interest in part number 9452968-01, a Drs Network And Imaging Systems Llc product we have in stock that is listed alongside the NSN 6685014841772 and the description “Indicator Pressure.” As part number 9452968-01 is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number 9452968-01 is listed alongside the NSN 6685-01-484-1772, meaning that it also belongs to FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments. Furthermore, this NSN part is specifically manufactured under CAGE Code 24290, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
MRC | Criteria | Characteristic |
---|---|---|
FAAZ | Phase | SINGLE |
ACYN | Ac Voltage Rating | 90.0 VOLTS MINIMUM AND 264.0 VOLTS MAXIMUM |
ACDC | Current Type | AC |
BFQN | Display Type | LIQUID CRYSTAL |
ACZB | Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
HGTH | Height | 3.500 INCHES NOMINAL |
AEJZ | Depth | 9.000 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 PANEL |
CXCY | Part Name Assigned By Controlling Agency | CONTROLLER,PID PRESSURE,DIGITAL TYPE 651C |
ABGL | Width | 9.500 INCHES NOMINAL |
FEAT | Special Features | HINCLUDES ADJUSTABLE SOFT-START FUNCTIONS FOR EACH SET POINT,AS WELL AS OPEN AND CLOSE FUNCTINS TO MINIMIZE TURBULENCE IN THE CHAMBER;LOCAL/REMOTE TRANSDUCER ZEROING CAPABILITY;TWO RELAYS TO ACTIVATE OTHER SYSTEM FUNCTIONS, ORTO INDICATE IF PRESSURE DEVIATES FROM THE DESIRED SET POINT; AN LCD READOUT SHOWS VALVE POSITION AND DISPLAYS PRESSURE IN A WIDE RANGE OF ENGINEERING UNITS; FIVE REPROGRAMMABLE SET POINTS ARE PROVIDED FOR PRESSURE OR POSITION CONTROL |
AGAV | End Item Identification | REENTRY SYSTEM TEST SET(RSTS) |
MRC | Decoded Requirement | Clear Text Reply |
AMNL | Presentation Type | DIGITAL DISPLAY |
ASKX | Electrical Connection Quantity | 1 |