Thank you for taking an interest in part number 9780-0032D, a Aai Corporation product we have in stock that is listed alongside the NSN 4920013717871 and the description “Test Stand Hydrauli.” As part number 9780-0032D is readily available for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with important information such as your target price and expected shipping time frame so that we can best tailor a solution that caters to your unique needs and restrictions alike.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items you require for carrying out operations, we list all aerospace parts, military and defense parts, and other product offerings with all applicable information for identification. For example, part number 9780-0032D is listed alongside the NSN 4920-01-371-7871, meaning that it also belongs to FSC 4920 Aircraft Maintenance And Repair Shop Specialized Equipment. Furthermore, this NSN part is specifically manufactured under CAGE Code 05172, a unique identifier belonging to the manufacturer for a specific facility. With all of this in mind, kick off purchasing with us today and see why so many customers steadily choose us for their operational needs.
MRC | Criteria | Characteristic |
---|---|---|
SUPP | Supplementary Features | TRAILER MOUNTED CABINET WITH 4 APPX 10 INCH WHEELS |
CHGQ | Filtering System | INCLUDED |
RDAL | Reference Data And Literature | SERD NO. 1328 |
BGST | Pressure Rating | 3100.0 POUNDS PER SQUARE INCH NOMINAL |
RTSE | Relationship To Similar Equipment | 4920-00-104-7838 |
FEAT | Special Features | INSTRUMENTATION INCLUDES PRESSURE,FLOW,AND TEMPERATURE DISPLAY; HEAT EXCHANGER,DIESEL ENGINE (100 HP,2300 RPM),FUEL TANK-40 GALLON,RESERVIOR-55 GALLON,FLOWMETER,FILTRATION 3 MICRON ABSOLUTE |
FCLS | Functional Classification | GG-8.4 |
FTLD | Functional Description | DESIGNED TO PROVIDE A SOURCE OF HYD POWER UP TO 50 GPM AT 3100 PSIG WITH OPEN OR CLOSED LOOP OPERATION. USED TO OPERATE ACFT HYD SYS (SKYFROL) W/O RUNNING ENGINE PUMPS TO TEST THE LANDING GEAR AND CONTROL SYS; USED ALSO TO DRAIN,FLUSH,FILL,OR DEAERATE THE HYD SYSTEM |
AAYJ | Hydraulic Fluid Flow Rate | 50.0 GALLONS PER MINUTE |
ALBY | Usage Design | AIRCRAFT HYDRAULIC SYSTEM |
MRC | Decoded Requirement | Clear Text Reply |
AMQY | Installation Design | PORTABLE |
ZZZV | Fsc Application Data | E-8A ACFT AGE. |