Item Name Transformerassembly
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5950 Coils and Transformers
National Item Identification Number (NIIN) 01-318-6661 (013186661)
NCB Code USA (01)
Manufacturer General Dynamics Ots Global Inc
Part Number Manufacturer Item Name Cage Code RFQ
11-00151-001 general dynamics ots global inc transformerassembly 21562 RFQ
500471-1 general dynamics ots global inc transformerassembly 21562 RFQ

Technical Characteristics of NSN 5950013186661

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABHPOVERALL LENGTH2.390 INCHES MINIMUM AND 2.430 INCHES MAXIMUM
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.730 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.770 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.410 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.450 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKWOVERALL HEIGHT5.068 INCHES MINIMUM AND 5.088 INCHES MAXIMUM
ABMKOVERALL WIDTH2.117 INCHES MINIMUM AND 2.217 INCHES MAXIMUM
ABTDMOUNTING SLOT WIDTH0.115 INCHES MINIMUM SINGLE GROUP AND 0.135 INCHES MAXIMUM SINGLE GROUP
ACZBFREQUENCY RATING400.0 HERTZ NOMINAL ALL COMPONENTS
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
ACZFMAXIMUM TRANSFORMER POWER RATING195.5 VOLT-AMPERE ALL COMPONENTS
ACZXWINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS
AEHZMAXIMUM OPERATING TEMP104.0 DEG CELSIUS
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
AXGYMOUNTING METHODSLOT SINGLE GROUP
BKPLRATING METHODELECTRICAL ALL COMPONENTS ALL SECONDARY
BKPLRATING METHODELECTRICAL ALL COMPONENTS SINGLE PRIMARY
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY 1ST COMPONENT AND 2 SECONDARY 1ST COMPONENT
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT
CRBZWINDING OPERATING CURRENT1.7 AMPERES AC NOMINAL ALL COMPONENTS SINGLE PRIMARY
CRBZWINDING OPERATING CURRENT100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT15.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT640.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT75.0 MILLIAMPERES AC MINIMUM 1ST COMPONENT 2ND SECONDARY AND 400.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT800.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.0886 1ST COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.540 2ND COMPONENT 4TH SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.700 ALL COMPONENTS SINGLE PRIMARY
CRGSDC RESISTANCE RATING IN OHMS0.7932 2ND COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS4.300 2ND COMPONENT 3RD SECONDARY
CRGSDC RESISTANCE RATING IN OHMS52.200 2ND COMPONENT 2ND SECONDARY
CRGSDC RESISTANCE RATING IN OHMS7.800 1ST COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING19.44 VOLTS-AMPERES 1ST COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING195.5 VOLTS-AMPERES ALL COMPONENTS SINGLE PRIMARY
CRMJWINDING POWER RATING2.4 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING2.56 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY
CRMJWINDING POWER RATING2.62 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING44.96 VOLTS-AMPERES 1ST COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING45.824 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL ALL COMPONENTS SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE14.70 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 56.90 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 71.60 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE159.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE24.30 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE25.60 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE26.20 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY
CWJSWINDING OPERATING VOLTAGE33.85 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 38.30 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 41.50 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 70.90 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 74.10 AC VOLTS NOMIN
TESTTEST DATA DOCUMENT16340-11-00151 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA
TTQYTERMINAL TYPE AND QUANTITY30 TURRET

Relevant Components for NSN - 5950-01-318-6661, 5950013186661
5960-00-188-0930 (5960001880930) 5905-01-265-9950 (5905012659950) 5995-01-379-1584 (5995013791584) 5962-01-243-3066 (5962012433066)
5995-01-565-3889 (5995015653889) 5985-00-438-3422 (5985004383422) 5995-01-570-5082 (5995015705082) 5935-01-232-5654 (5935012325654)
5935-00-925-1739 (5935009251739) 5985-01-314-9148 (5985013149148) 5998-01-280-1852 (5998012801852) 5935-01-310-6114 (5935013106114)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top