Thank you for taking an interest in the NSN 5950-00-279-4018 supplies and listing resources that we provide on Integrated Military Parts. At the top of this page, you will find an overview of NSN 5950-00-279-4018, including details on its associated item name, Federal Supply Group, Federal Supply Class, and more. You can also review a list of all manufacturers that our stock traces back to, each serving as a link to expanded catalogs if you wish to further your search.
Underneath our overview, part numbers like 25P237501-21-11, TT1-10835, and others that belong to our NSN 5950-00-279-4018 inventory have been listed out for your perusal. If any are of interest to you, click on the “RFQ” button to its right to access a quote request form. By filling out and submitting a form with detailed information on your requirements and expectations, you will be able to secure fully customized quotes for your comparisons. You can rest assured that you will receive highly competitive options when you shop on Integrated Military Parts, our staff working tirelessly to ensure streamlined fulfillment and satisfaction. Knowing how we intend to serve you, continue perusing solutions on this catalog and reach out as soon as you are ready.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-279-4018 (002794018) |
NCB Code | USA (00) |
Manufacturer | Herley Chicago, Transformer Technicians Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
25P237501-21-11 | herley chicago | transformer power | 98738 | RFQ |
TT1-10835 | transformer technicians inc | transformer power | 96253 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.030 INCHES MAXIMUM SINGLE MOUNTIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.410 INCHES MAXIMUM SINGLE MOUNTIN |
ABMK | OVERALL WIDTH | 2.120 INCHES MAXIMUM2.120 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.940 INCHES MAXIMUM3.940 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 185.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY130.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 552.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY236.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 9 SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 27 STANDOFF,SOLDER LUG |
Relevant Components for NSN - 5950-00-279-4018, 5950002794018 | ||||
5996-01-382-2114 (5996013822114) | 5950-00-961-5897 (5950009615897) | 5998-01-407-7137 (5998014077137) | 5905-00-868-4371 (5905008684371) | |
5962-01-660-2830 (5962016602830) | 5962-01-052-0540 (5962010520540) | 5961-00-854-3044 (5961008543044) | 5970-01-494-6799 (5970014946799) | |
5963-01-714-1994 (5963017141994) | 5995-01-086-1797 (5995010861797) | 5940-00-416-5406 (5940004165406) | 5996-01-313-2637 (5996013132637) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote