MRC | Criteria | Characteristic |
---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.031 INCHES MINIMUM AND 2.093 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS AND 15.0 AMPERES DC ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
MRC | Decoded Requirement | Clear Text Reply |
TEST | Test Data Document | MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND MIL-STD-202 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 80.0 DC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AJEC | Boss Height | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.469 INCHES MINIMUM AND 1.531 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
THSD | Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.138 INCHES |
CBBL | Features Provided | HIGH INRUSH PROTECTION |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 1.829 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
CXCY | Part Name Assigned By Controlling Agency | CIRCUIT BREAKER |
ADAQ | Body Length | 2.469 INCHES MINIMUM AND 2.531 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.909 INCHES MINIMUM AND 1.971 INCHES MAXIMUM |
AGAV | End Item Identification | MISSLE, MINUTEMAN LGM-30, RUN IN CONSOLE |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.700 MINIMUM AT 200 PCT ALL LOCATIONS AND 18.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |