Thank you for taking an interest in the NSN 5925-01-501-6457 supplies and listing resources that we provide on Integrated Military Parts. At the top of this page, you will find an overview of NSN 5925-01-501-6457, including details on its associated item name, Federal Supply Group, Federal Supply Class, and more. You can also review a list of all manufacturers that our stock traces back to, each serving as a link to expanded catalogs if you wish to further your search.
Underneath our overview, part numbers like IULHK1119-1REC4-30372-22, and others that belong to our NSN 5925-01-501-6457 inventory have been listed out for your perusal. If any are of interest to you, click on the “RFQ” button to its right to access a quote request form. By filling out and submitting a form with detailed information on your requirements and expectations, you will be able to secure fully customized quotes for your comparisons. You can rest assured that you will receive highly competitive options when you shop on Integrated Military Parts, our staff working tirelessly to ensure streamlined fulfillment and satisfaction. Knowing how we intend to serve you, continue perusing solutions on this catalog and reach out as soon as you are ready.
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-501-6457 (015016457) |
NCB Code | USA (01) |
Manufacturer | Sensata Technologies Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
IULHK1119-1REC4-30372-22 | sensata technologies inc | circuit breaker | 81541 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.250 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC THIRD LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 120.0 MILLIAMPERES DC FOURTH LOCATION |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 70.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AJEC | Boss Height | 1.042 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED STUD |
ADAT | Body Width | 2.490 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
AGAV | End Item Identification | 5895-01-467-7213 |
ADTV | Case Material | METAL |
FEAT | Special Features | 1ST POLE HAS SINGLE POLE DOUBLE THROW AUXILIARY SWITCH |
AJWX | Mounting Surface To Terminal End Distance | 2.529 INCHES NOMINAL |
ADAQ | Body Length | 3.015 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT FIRST LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT THIRD LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.000 NOMINAL AT 125 PCT FOURTH LOCATION |
THSD | Thread Series Designator | UNC |
MRC | Decoded Requirement | Clear Text Reply |
Relevant Components for NSN - 5925-01-501-6457, 5925015016457 | ||||
5930-01-014-4841 (5930010144841) | 5961-01-092-9500 (5961010929500) | 5999-01-257-1020 (5999012571020) | 5970-00-098-9810 (5970000989810) | |
5945-01-111-1628 (5945011111628) | 5905-00-467-7350 (5905004677350) | 5995-00-459-4116 (5995004594116) | 5975-01-216-8288 (5975012168288) | |
5977-00-296-5375 (5977002965375) | 5961-01-069-7734 (5961010697734) | 5930-00-491-1425 (5930004911425) | 5998-01-546-2893 (5998015462893) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote