Item Name | Circuitbreaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 01-406-3453 (014063453) |
NCB Code | USA (01) |
Manufacturer | Eaton Corporation, Engineered Air Systems Inc, Drs Environmental Systems Inc, Heinemann Electric Co Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
CF6-G8-AB0060-100B | eaton corporation | circuitbreaker | 74193 | RFQ |
62165-1 | engineered air systems inc | circuitbreaker | 90598 | RFQ |
CF6-G8-AB-W-0060-100B | eaton corporation | circuitbreaker | 1w134 | RFQ |
62165-1 | drs environmental systems inc | circuitbreaker | 5rql2 | RFQ |
CF6-G8-AB-W-60-480AC-100 | heinemann electric co inc | circuitbreaker | l3330 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.750 INCHES NOMINAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
ADAQ | BODY LENGTH | 5.800 INCHES NOMINAL |
AKPX | POLE QUANTITY | 6 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 12 THREADED HOLE |
TTQY | TERMINAL TYPE AND QUANTITY | 12 COMPRESSION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 460.0 AC ALL LOCATIONS |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.026 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.276 INCHES NOMINAL |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60.0 AMPERES AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
AJEC | BOSS HEIGHT | 0.219 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4.750 INCHES NOMINAL |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.026 INCHES NOMINAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 6 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, FOUR, FIVE, AND SIX LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 50.000 MINIMUM AT 200 PCT AND 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.609 INCHES NOMINAL |
Relevant Components for NSN - 5925-01-406-3453, 5925014063453 | ||||
5930-01-201-0344 (5930012010344) | 5935-00-733-6624 (5935007336624) | 5935-01-670-0032 (5935016700032) | 5935-01-238-8280 (5935012388280) | |
5945-00-772-0597 (5945007720597) | 5998-01-470-7299 (5998014707299) | 5998-01-450-1035 (5998014501035) | 5995-01-305-0350 (5995013050350) | |
5935-01-438-9012 (5935014389012) | 5998-01-080-8351 (5998010808351) | 5998-01-518-1172 (5998015181172) | 5935-01-141-2602 (5935011412602) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote