MRC | Criteria | Characteristic |
---|
AFGA | OPERATING TEMP RANGE | -55.0 TO 100.0 DEG CELSIUS |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 6TH RADIO INTERFERENCE 6TH FUNCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
ABTD | MOUNTING SLOT WIDTH | 0.195 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.800 INCHES MAXIMUM |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND 3RD FUNCTION |
CQRG | BODY MATERIAL | ALUMINUM |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.375 INCHES NOMINAL |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 81205 |
AHCG | MAXIMUM TEMP RISE | 20.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCASED |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 800.0 VOLTS AT SEA LEVEL |
CTJS | UNPACKAGED UNIT WEIGHT | 6.000 POUNDS NOMINAL |
ABKW | OVERALL HEIGHT | 4.487 INCHES NOMINAL |
ADAQ | BODY LENGTH | 6.200 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.6 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBP | INPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
FEAT | SPECIAL FEATURES | SIX FILTERED FUNCTIONS |