MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 13.600 INCHES MINIMUM AND 13.660 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 2.530 INCHES MINIMUM AND 2.590 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 7.600 INCHES MINIMUM AND 7.660 INCHES MAXIMUM |
ADAT | BODY WIDTH | 10.100 INCHES MINIMUM AND 10.160 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 5.0 TO 200.0 |
AFGA | OPERATING TEMP RANGE | -46.0 TO 85.0 DEG CELSIUS |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHCG | MAXIMUM TEMP RISE | 60.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CTJS | UNPACKAGED UNIT WEIGHT | 12.000 POUNDS NOMINAL |
FEAT | SPECIAL FEATURES | REMOVEABLE TERMINAL COVERS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
ZZZK | SPECIFICATION/STANDARD DATA | 80063-SM-A-919007 MANUFACTURERS SOURCE CONTROL |