Thank you for taking an interest in the NSN 5915-00-878-3522 supplies and listing resources that we provide on Integrated Military Parts. At the top of this page, you will find an overview of NSN 5915-00-878-3522, including details on its associated item name, Federal Supply Group, Federal Supply Class, and more. You can also review a list of all manufacturers that our stock traces back to, each serving as a link to expanded catalogs if you wish to further your search.
Underneath our overview, part numbers like JN14-684A, 8001-28-11PFP, 049-000191, RF03178, RF3178, and others that belong to our NSN 5915-00-878-3522 inventory have been listed out for your perusal. If any are of interest to you, click on the “RFQ” button to its right to access a quote request form. By filling out and submitting a form with detailed information on your requirements and expectations, you will be able to secure fully customized quotes for your comparisons. You can rest assured that you will receive highly competitive options when you shop on Integrated Military Parts, our staff working tirelessly to ensure streamlined fulfillment and satisfaction. Knowing how we intend to serve you, continue perusing solutions on this catalog and reach out as soon as you are ready.
Item Name | Filter Radio Frequency Interfere |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5915 Filters and Networks |
National Item Identification Number (NIIN) | 00-878-3522 (008783522) |
NCB Code | USA (00) |
Manufacturer | Sprague Electric Co, Sealtron Inc, Fil Coil Inc, Northrop Grumman Systems Corporation, Ems Development Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
JN14-684A | sprague electric co | filter radio frequency interfere | 56289 | RFQ |
8001-28-11PFP | sealtron inc | filter radio frequency interfere | 97814 | RFQ |
049-000191 | fil coil inc | filter radio frequency interfere | 56528 | RFQ |
049-000191 | northrop grumman systems corporation | filter radio frequency interfere | 26916 | RFQ |
RF03178 | ems development corporation | filter radio frequency interfere | 13619 | RFQ |
RF3178 | ems development corporation | filter radio frequency interfere | 13619 | RFQ |
JN14-201 | sprague electric co | filter radio frequency interfere | 56289 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ADAT | BODY WIDTH | 2.375 INCHES NOMINAL |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.015 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 250.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
CTJS | UNPACKAGED UNIT WEIGHT | 35.000 OUNCES NOMINAL |
FEAT | SPECIAL FEATURES | 21 FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
ABKW | OVERALL HEIGHT | 5.307 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.812 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.500 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.437 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.500 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AFSV | AVERAGE LIFE RATING IN HOURS | 250.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.05 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.05 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 250.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 250.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 250.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 250.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 250.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CONNECTOR 1ST FUNCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 21 TAB,SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 300.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 25.0 VOLTS AC 3RD RADIO INTERFERENCE AND 200.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
Relevant Components for NSN - 5915-00-878-3522, 5915008783522 | ||||
5996-01-382-2114 (5996013822114) | 5950-00-961-5897 (5950009615897) | 5998-01-407-7137 (5998014077137) | 5905-00-868-4371 (5905008684371) | |
5962-01-660-2830 (5962016602830) | 5962-01-052-0540 (5962010520540) | 5961-00-854-3044 (5961008543044) | 5970-01-494-6799 (5970014946799) | |
5963-01-714-1994 (5963017141994) | 5995-01-086-1797 (5995010861797) | 5940-00-416-5406 (5940004165406) | 5996-01-313-2637 (5996013132637) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote