MRC | Criteria | Characteristic |
---|
ADAQ | BODY LENGTH | 2.160 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.340 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.860 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 6TH RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES |
CQRG | BODY MATERIAL | METAL |
FEAT | SPECIAL FEATURES | 14 SECTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |