Thank you for taking an interest in the NSN 5905-00-139-1820 supplies and listing resources that we provide on Integrated Military Parts. At the top of this page, you will find an overview of NSN 5905-00-139-1820, including details on its associated item name, Federal Supply Group, Federal Supply Class, and more. You can also review a list of all manufacturers that our stock traces back to, each serving as a link to expanded catalogs if you wish to further your search.
Underneath our overview, part numbers like 44005X, 44087, B603301006, and others that belong to our NSN 5905-00-139-1820 inventory have been listed out for your perusal. If any are of interest to you, click on the “RFQ” button to its right to access a quote request form. By filling out and submitting a form with detailed information on your requirements and expectations, you will be able to secure fully customized quotes for your comparisons. You can rest assured that you will receive highly competitive options when you shop on Integrated Military Parts, our staff working tirelessly to ensure streamlined fulfillment and satisfaction. Knowing how we intend to serve you, continue perusing solutions on this catalog and reach out as soon as you are ready.
Item Name | Resistor Thermal |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-139-1820 (001391820) |
NCB Code | USA (00) |
Manufacturer | Ysi Incorporated, Kearfott Corporation |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 3.000 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.095 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.008 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 10.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 1.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -10.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 10.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 30.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 70.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.1 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 105.2 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 16.6 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.4 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 203.8 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 421.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 525.4 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 53.1 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 55.6 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.0 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.7 TO 0.7 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.7 TO 0.7 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.8 TO 0.8 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.9 TO 0.9 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.9 TO 0.9 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.3 TO 1.3 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.5 TO 1.5 9TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.1 TO 2.1 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.2 TO 2.2 10TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -4.0 TO 4.0 1ST RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | ZERO POWER RESISTANCE | 3.000 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -1.02/1.02 |
STYL | STYLE DESIGNATOR | BEAD |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
Relevant Components for NSN - 5905-00-139-1820, 5905001391820 | ||||
5940-01-668-3885 (5940016683885) | 5935-01-261-9035 (5935012619035) | 5930-01-460-7697 (5930014607697) | 5975-00-604-8537 (5975006048537) | |
5935-01-030-9330 (5935010309330) | 5998-01-604-3341 (5998016043341) | 5950-00-503-8691 (5950005038691) | 5998-01-161-5746 (5998011615746) | |
5925-01-282-6899 (5925012826899) | 5996-00-863-6026 (5996008636026) | 5935-01-414-9166 (5935014149166) | 5999-01-296-7109 (5999012967109) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote